Sign In | Join Free | My gimpguru.org
China Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd logo
Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd
Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd Become a World-class Air Separation Unit And Gas Operation's Specialist.
Active Member

9 Years

Home > Nitrogen Generation Plant >

Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h

Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd

Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h

  • 1
  • 2
  • 3

Brand Name : Hangyang

Model Number : KDN

Certification : CE/ASEM/GB

Place of Origin : China

MOQ : 1 set

Price : according to actual requirement

Payment Terms : negotiation

Supply Ability : according to actual requirement

Delivery Time : according to actual requirement

Packaging Details : wooden case, nude packing, container

Product Name : Nitrogen generation plant 4800 Nm3/h / 40 Nm3/h KDN-4800/40Y

Application : Glass,Oil and Gas Field,Machinery & Construction,Metallurgy

Output(Nm3/h) : 4500~5000

Standard : CE/ASEM/GB

Pressure : 0.01/0.15

Service : Engineers available to commissioning service overseas

Delivery Term : FOB Shanghai

Contact Now

Nitrogen generation plant 4800 Nm3/h / 40 Nm3/h KDN-4800/40Y

Specifications:

The Standard Products for the Nitrogen Generator KDN 4500~ 5000 Series

MODEL

CONTENTS

KDN-4500/200Y

KDN-4800/200Y

KDN-4200/420Y

KDN-4820/300Y

GAN/LIN flow

Nm3/h

4500/200

4800/200

4800/420

4820/300

GAN/LIN purity

ppm

10ppm(O2)

10ppm(O2)

1ppm(O2)

5ppm(O2)

GAN/LIN pressure

MPa

0.7

0.7

0.7

0.67

Subcooled

13/-172

13/-173

13/-173

13/-174

Typical Product: KDN-4800/40Y Nitrogen generation plant

Output, purity and pressure

Flow (Nm3/h)

Purity

Pressure MPa(G)

Subcooled (℃)

GAN/LN

4800 Nm3/h / 40 Nm3/h

≤3ppm(O2)

0.01/0.15

14/-192

Description:

First step: air goes through filter to remove dust and mechanical impurities

Second step: air goes into compressor to be compressed

Third step: air goes into pre-cooling unit to be cooled to 5~8℃ and to saturated condition

Forth step: air goes into molecular sieve (such as MS1) to adsorb hydrocarbon like H2O, CO2, C2H2

Fifth step: air is divided into three steams: one steam as instrument air, the second steam flows into the main heat exchanger E1 directly to be cooled, and then part of it will reach saturation temperature after going out of E1, and then goes to the bottom of lower column C1 to follow the rectification; the third steam goes to the main heat exchanger after being boosted and cooled in the boosting end of expander, and then it is withdrawn from the middle of heat exchanger to the expander for expansion refrigeration, and part expanded air will be fed to the upper column to follow the rectification, and the rest goes out of cold box after it backflows to the main heat exchanger and be rewarmed.

Sixth step: air is separated into pure liquid nitrogen and liquid air after being rectified in the lower column. The liquid air in the bottom of lower column goes into the lower part of upper column through sub-cooling throttling, and then flows into the condensation evaporator as the cold source of condensation rising nitrogen by the column plate.

For the liquid nitrogen in the top of lower column, part of it will be drawn out and go to the top of upper column to follow the rectification, and the rest will be extracted as product.

 The oxygen enriched gas in the bottom of upper column is drawn out and goes into the sub-cooler and main heat exchanger to be re-warmed, and then goes out of cold box to be as the regeneration gas of molecular sieve adsorber.

 The nitrogen in the top of upper column will be withdrawn as the product, and goes out of cold box after being re-warmed in the sub-cooler and main heat exchanger, and then fed to the piping net after being boosted to the pressure required by the user.

 In order to make sure the safe running of plant, a small part liquid in the condensation evaporator should be discharged out of column regularly to avoid the accumulation of hydrocarbon, especially acetylene.

Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h

Applications:

  1. Modified Atmosphere Gas
  2. Inert Gas
  3. Nitrogen Purging & Pressurize Test
  4. Agriculture
  5. Pharmaceutical and biotechnology
  6. Petroleum and natural gas

Competitive Advantage:

  1. Very simple and safe to operate
  2. Low Maintenance Cost
  3. Short time delivery. Good service.
  4. Successful experience of made many plants
  5. No loss, high returns


Product Tags:

liquid nitrogen plants

      

nitrogen generator system

      
Quality Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h wholesale

Professional PSA Nitrogen Generation Plant 4800 Nm3/h / 40 Nm3/h Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hangzhou Hangyang Cryogenic Liquefaction Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)